Search results for "Intermethod comparison"

showing 5 items of 5 documents

Inferring causation from time series in earth system sciences

2019

The heart of the scientific enterprise is a rational effort to understand the causes behind the phenomena we observe. In large-scale complex dynamical systems such as the Earth system, real experiments are rarely feasible. However, a rapidly increasing amount of observational and simulated data opens up the use of novel data-driven causal methods beyond the commonly adopted correlation techniques. Here, we give an overview of causal inference frameworks and identify promising generic application cases common in Earth system sciences and beyond. We discuss challenges and initiate the benchmark platform causeme.net to close the gap between method users and developers.

0301 basic medicineEarth scienceAquatic Ecology and Water Quality ManagementDynamical systems theoryComputer science530 PhysicsDatenmanagement und AnalyseSciencereviewGeneral Physics and Astronomyheart02 engineering and technologyGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciencesDatabasesLife ScienceCausationStatistical physics thermodynamics and nonlinear dynamicsintermethod comparisonlcsh:Scienceresearch workScientific enterpriseMultidisciplinaryWIMEKSeries (mathematics)QComputational sciencefeasibility study500General ChemistryAquatische Ecologie en Waterkwaliteitsbeheersimulation021001 nanoscience & nanotechnologyData sciencecausal inference climateEarth system scienceEnvironmental sciences030104 developmental biologytime series analysisCausal inferencePerspectiveBenchmark (computing)Observational studylcsh:Qconceptual frameworkdata management0210 nano-technologyClimate sciences
researchProduct

Diagnóstico etilógico de la disfunción ventricular izquierda con tomografia computerizada: comparación con coronariografía y cardiorresonancia

2012

[EN] Introduction and objectives To evaluate the capability of multidetector computed tomography to diagnose the coronary etiology of left ventricular dysfunction compared with using invasive coronary angiography and magnetic resonance. Methods Forty consecutive patients with left ventricular dysfunction of uncertain etiology underwent invasive coronary angiography and contrast magnetic resonance. All patients were evaluated with multidetector computed tomography including coronary calcium presence and score, noninvasive coronary angiography, and myocardial tissue assessment. Results The sensitivity and specificity of the presence of coronary calcium to identify left ventricular dysfunction…

Coronary angiographyMaleScoring systemCardiac magnetic resonanceCoronary angiographyESTADISTICA E INVESTIGACION OPERATIVACoronariografíaComputed tomographyReviewCoronary Artery DiseaseCoronary AngiographyDiagnostic accuracyVentricular Dysfunction LeftProspective StudiesAged 80 and overmedicine.diagnostic_testAngiocardiographyCalcinosisGeneral MedicineMiddle AgedMagnetic Resonance ImagingInvasive coronary angiographySensitivity and specificityCardiologycardiovascular systemTomografía computarizada con multidetectoresFemaleRadiologyHumanAdultmedicine.medical_specialtyContrast enhancementClinical articleSensitivity and SpecificityHeart left ventricle failureSingle testMultidetector computed tomographyNecrosisInternal medicineMultidetector computed tomographyMultidetector Computed TomographymedicineHumansClinical evaluationcardiovascular diseasesAgedCardiac patientbusiness.industryIntermethod comparisonMagnetic resonance imagingResonancia magnética cardiacaEtiologyCalciumCardiovascular magnetic resonanceAgatston calcium scoreCardiac magnetic resonancebusinessControlled study
researchProduct

Yellow (577 nm) micropulse laser versus half-dose verteporfin photodynamic therapy in eyes with chronic central serous chorioretinopathy: results of …

2018

PurposeTo compare the functional and anatomical outcomes of eyes with chronic central serous chorioretinopathy treated with yellow micropulse (MP) laser versus half-dose verteporfin photodynamic therapy (PDT).MethodsThis is a multicentre, retrospective comparative study of 92 eyes treated with yellow MP laser (duty cycle of 5%, zero spacing between spots, spot size varied from 100 to 200 µm, power varied from 320 to 660 mW, and the pulse burst duration was 200 ms) and 67 eyes treated with PDT (half-dose verteporfin (3 mg/m2) infused over 10 min), followed by laser activation for 83 s. Spot sizes varied from 400 to 2000 µm.ResultsIn the MP group, at 12 months of follow-up, the mean best corr…

Laser surgeryMaleFluorescein angiographyretinaVisual acuityoptical coherencegenetic structuresPhysiologymedicine.medical_treatmentCentral serous chorioretinopathyVisual AcuityPhotodynamic therapytreatment lasersProceduresPhotodynamic therapychemistry.chemical_compound0302 clinical medicineBest corrected visual acuityMedicineFluorescein AngiographyTreatment outcomeMiddle agedTomographyPriority journalLow level laser therapyPhotosensitizing Agentsmedicine.diagnostic_testMiddle AgedFluorescein angiographyVerteporfinPhotosensitizing agentsSensory SystemsIndocyanine greenMulticenter studyBevacizumabClinical trialRetrospective studyTreatment OutcomeCentral Serous ChorioretinopathyFemaleLaser Therapymedicine.symptomTomography Optical Coherencemedicine.drugHumanIndocyanine GreenAdultmedicine.medical_specialtyVisual acuityLaser surgeryMajor clinical studyFollow-up studiesPathophysiologyArticleChronic disease03 medical and health sciencesCellular and Molecular NeuroscienceLaser therapyOphthalmologyFluorescence angiographyHumansmaculaLow level laser therapyRetrospective StudiesDisease durationPhotosensitizing agentOptical coherence tomographybusiness.industryIntermethod comparisonSubretinal neovascularizationCentral serous retinopathyVerteporfinFollow upmedicine.diseaseMulticenter study (topic)eye diseasesRetrospective studiesOphthalmologyCentral serous retinopathychemistryPhotochemotherapyChronic Disease030221 ophthalmology & optometryYellow micropulse laserComparative studysense organsbusinessIndocyanine greenControlled study030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Validity of needle core biopsy in the histological characterisation of mammary lesions

2006

Summary Over the last few years, there has been an enormous increase in the use of needle core biopsy (CB) for the histopathological characterisation of suspect lesions of the breast. The aim of this study was to verify the diagnostic reliability of CB by comparing the histological results obtained with the use of this technique with those obtained from the whole of the surgically resected specimen. We studied 198 out of 426 patients with clinically and/or radiologically suspect breast lesions. We found correspondence between the histological examination of the whole of the excised specimen and that of the CB in 94.9% of the cases of infiltrating carcinoma and in 71.4% of those involving du…

Pathologymedicine.medical_specialtyReproducibility of ResultBreast NeoplasmsSensitivity and SpecificityBreast cancerNeedle core biopsyRetrospective StudiemedicineCarcinomaHumansbreast carcinomahumanintermethod comparisonarticle; breast carcinoma; breast disease; carcinoma in situ; diagnostic accuracy; diagnostic value; histopathology; human; human tissue; intermethod comparison; intraductal carcinoma; major clinical study; needle biopsy; prediction; priority journal; reliability; sensitivity and specificity; validation process Biopsy Needle; Breast Neoplasms; Carcinoma Ductal Breast; Carcinoma Intraductal Noninfiltrating; Female; Humans; Reproducibility of Results; Retrospective Studies; Sensitivity and Specificity [EMTREE medical terms]Retrospective Studiesintraductal carcinomaHistological examinationreliabilitybusiness.industryBiopsy Needlevalidation process MeSH: Biopsy NeedleCarcinoma Ductal Breastbreast diseaseReproducibility of Resultscarcinoma in situneedle biopsypredictionGeneral Medicinemedicine.diseasemajor clinical studyPredictive valuehuman tissueCarcinoma Intraductal Noninfiltratingpriority journalhistopathologyEMTREE medical terms: articlediagnostic accuracyFemaleSurgerydiagnostic valueRadiologybusinessCore biopsyBreast NeoplasmThe Breast
researchProduct

Dynamic aphasia and the generation of language

2004

Severely reduced propositional speech in the context of intact nominal language skills (i.e., repetition, naming, comprehension, and reading) is the hallmark of dynamic aphasia (Luria, 1970). Recent evidence suggests there may be different types of dynamic aphasia as some patients do not produce any response on verbal generation tasks, whilst others are able to perform normally on verbal genera- tion tasks. For example, Robinson and colleagues (Robinson, Blair, & Cipolotti, 1998; Robinson, Shallice, & Cipolotti, 2004) reported two dynamic aphasics who failed to produce a verbal response when many verbal response options were activated by a stimulus, but not when a dominant response was avai…

Speech and HearingLinguistics and LanguageSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaCognitive NeuroscienceAphasiacorrelation analysis dynamic aphasia human intermethod comparison interview language scoring system speech speech articulationstatistical analysismedicineExperimental and Cognitive Psychologymedicine.symptomPsychologyLanguage and LinguisticsCognitive psychology
researchProduct